For over five decades, the Redland 49 tiles have left a permanent mark on London's skyline, defining its unique roofscapes with an exceptional blend of strength and aesthetic charm. A compact version brings you all these benefits in a lighter package. This smaller format not on...Read More
For over five decades, the Redland 49 tiles have left a permanent mark on London's skyline, defining its unique roofscapes with an exceptional blend of strength and aesthetic charm. A compact version brings you all these benefits in a lighter package.
This smaller format not only boasts a reduced unit weight but also ensures effortless handling and installation. These Redland 49 tiles are an incredibly economical and practical option for your roofing needs.
The through-coloured tiles are suitable for a minimum pitch of 17.5° with a 100mm headlap or 22.5° with a 75mm headlap. The granular tiles can be installed with a minimum pitch of 22.5° and a 100mm headlap or 30° with a 75mm headlap. The maximum pitch can reach up to 90°, depending on your specific fixing specifications. Ensure a secure installation with a maximum headlap of 125mm. For optimal performance, choose a minimum gauge of 257mm. For through-coloured tiles, the maximum gauge is 282mm for pitches below 22.5° and 307mm for pitches at 22.5° and above. For granular tiles, the maximum gauge is 282mm for pitches below 30° and 307mm for pitches at 30° and above.
At a gauge of 282mm, you can achieve coverage of 17.8 tiles per square metre. Increase the gauge to 307mm for a slightly denser coverage of 16.3 tiles per square metre. Choose the appropriate batten size based on your rafter centres. For rafter centres up to 450mm, use the 38mm x 25mm batten size. If you have wider rafter centres up to 600mm, opt for the 50mm x 25mm batten size. To meet your batten requirements, you'll need approximately 3.56 metres of battens per square metre at a 282mm gauge or around 3.26 metres per square metre at a 307mm gauge.
There are no product downloads to show.
Question:
Is it possible to order a sample of a Tudor brown redland 49 please?
Answer:
Samples of Redland tiles can be ordered from them directly via the below link.
https://redland.co.uk/services/sample-request
Question:
What is minmium pitch these tile can be used (granular) with a head lap of 125mm?
Answer:
Granular at 100mm headlap would be 22.5°.
Smooth finish tiles at 10000 headlap would be 17.5°.
These Slate Grey tiles are actually in the smooth finish, not granular.
Question:
What is the lowest pitch for this tile
Answer:
Minimum pitch :
Through coloured
17.5° at 100mm headlap.
Pay in 4 interest-free payments of £107.9075
Learn more