Marley 600mm x 600mm Birkdale Man-Made Fibre Cement Slate - Heather Our slates are usually delivered on a Six Wheeled Lorry (11m Long & 2.4m Wide) with a Tail-Lift facility to off-load on solid level ground with a Pump Truck. Non compliance to delivery restr... Read More
Marley 600mm x 600mm Birkdale Man-Made Fibre Cement Slate - Heather
Our slates are usually delivered on a Six Wheeled Lorry (11m Long & 2.4m Wide) with a Tail-Lift facility to off-load on solid level ground with a Pump Truck.
Non compliance to delivery restrictions may result in additional Delivery Charges.
Should you specifically require Crane Off-Load or small vehicle please notify us at the time of ordering, as an additional charge may be incurred.
Smooth Face / Riven Edge.
Description
Featuring a smooth surface and dressed edges Birkdale fibre cement slates offer a traditional and pleasing look at an affordable price.
The combination of colour, edge finish and design flexibility that the Birkdale offers means it is ideal as both a roofing and cladding solution, used on numerous projects including the Tally Ho training centre in Birmingham and the Holcombe Moor Army base near Bury.
Size of tile
600mm x 300mm.
600mm x 300mm Minimum pitch (100mm lap)
Moderate exposure 22.5°.
Severe exposure 25°.
600mm x 300mm Minimum pitch (110mm lap).
Moderate exposure 20°.
Severe exposure 22.5°.
Maximum pitch
90°.
Maximum guage
600mm x 300mm.
245-250mm.
Covering capacity
Net slates/m².
600mm x 300mm.
100mm lap 13.4/m2.
110mm lap 13.6/m2.
Weight of tiling
Approx.kg/m².
600mm x 300mm.
100mm lap 20.4 (0.20kN/m²).
110mm lap 20.9 (0.20kN/m²).
Battens required
(net lin.m/m²).
600mm x 300mm.
100mm lap 4.00.
110mm lap 4.08.
Batten size
38 x 25 mm for rafters / supports not exceeding 450mm centres.
50 x 25mm for rafters / supports not exceeding 600mm centres.
Tile nails
Slate nails (Copper to BS1202-2) 30mm x 2.65mm.
Copper disc rivets
Required.
Authority
BS EN 492.
Notes
Fibre cement slates meet the strength requirements of BS EN 492, achieving an average bending moment greater than 50Nm/m (Class B).
The slates also have a minimum density of 1700kg/m³ and a nominal thickness of 4mm.
The batch code printed onto the underside of the slates is in the following format:
Example: NT UG21WB 24/11/11 12.10 CE.
NT = Type of Product (ie. Non asbestos technology).
UG21 = Product code.
W = Manufacturing plant ID.
B = Class (for bending moment).
24/11/11 = Date of manufacture.
12.10 = Time of manufacture.
CE = CE Mark.
The effectiveness of the tile or slate to operate at the minimum recommended pitch and lap may be influenced by special circumstances.
Guidance on pitch and lap should be obtained from the Technical Advisory Service for the following:
• Interlocking tiles and slates where the roof slope exceeds 6 metres in length and/or the site is rated to be in a severe exposure category.
• Double-lap fibre cement slates where the roof slope exceeds 6 metres in length (severe/very severe exposure) and 9 metres in length (sheltered/moderate exposure).
Consideration should be given to sealing any cut edges to prevent potential efflorescence staining.